Node maintenance and upgrades

Upgrading or rebooting nodes one at a time is safe for the data: freeze volumes never diverge, and with only one side down at a time last-man-standing cannot split-brain either. Two rules keep it non-disruptive as well.

Wait for Ready between nodes. After a node rejoins, its legs resync from the surviving replicas and the affected volumes read Degraded until that finishes. Draining the next node inside that window takes the only UpToDate copy out of service: pods using those volumes cannot start anywhere, the RWX gateway has no healthy replica node to fail over to, and freeze volumes stop serving writes. No data is ever lost (DRBD refuses to serve stale legs), but every replicated volume goes unavailable until the drained node returns. Gate the loop on every volume being Ready again:

kubectl wait miroirvolumes --all \
  --for=jsonpath='{.status.phase}'=Ready --timeout=1h

miroir_volume_resync_ratio shows progress, and the starter alerts flag sustained degradation.

Cordon before rebooting. The agent releases its Secondary DRBD backings at shutdown only when the node is cordoned (the gate exists so routine pod restarts do not churn replication). kubectl drain and talosctl upgrade cordon for you; a bare reboot on a Debian/Ubuntu node does not, and risks the pool-export wedge the Requirements page warns about.

The per-node loop is therefore: cordon and drain, upgrade or reboot, wait for the node to rejoin, wait for Ready, uncordon, next node.

While a single node is down, replicated volumes keep serving per the quorum table (see At a glance), and the RWX gateway reschedules onto the surviving replica node (client I/O stalls for tens of seconds, never errors). Operations that need the missing node pause and converge when it returns rather than failing:

  • Creating a replicated volume whose placement needs the node (on a 2-node cluster, any replicated PVC) stays Pending: the initial sync needs every leg connected.
  • Expansion completes only once every diskful replica realizes the new size.
  • Snapshots of volumes with a leg on the node retry until the write barrier can span all connected legs.
  • Deleting such volumes blocks on the node's teardown finalizer.